ADP Housekeeping Data ===================== word# description ---------------------------------------------------------------------- 0 ADP mode (SRADPM of PT) 1 ADP software status bit# 15 FIFO full 14 ES signal 13 FIFO empty 12 ADP stopped data taking 11-8 SAS cadency (SCAD of PT, but 0 for 128Hz) 7-4 page of EEPROM programming 3-2 page of parameter EEPROM 1-0 page of boot EEPROM (comment: bits 3-0 is the status of the HW register after reset and bits 7-4 reflect the according SW variable) 2 no of RAS frames (interrupts) 3 no of SAS frames (interrupts) 4 no of communication interrupts (sum of all kind of comm. interrupts between ADP and IDPU) 5 control sum of program after ADPRESET (will change on running) 6 ADP HW mode (FLAGS of PT) 7 no of SAS limbs crossing threshold for the three current frames 8 no of RAS pixels above threshold for the current frame 9 SAS10: no of limbs 10 SAS11: no of limbs 11 SAS12: no of limbs 12 RAS: no of events 13 no of discarded frames: MSB: no of discarded SAS frames (SFD, frame overrun) LSB: no of discarded RAS frames (RFD, ES, frame overrun) 14 current ACS code 15 no of ES signals (total number of recovers from ES) 16 no of aquired RAS images 17 no of discarded SAS limbs (MISEP) 18 parameter table ID 19 on running: no of packets written to FIFO on programming: no of 64word packets written to EEPROM on message sending: no of x-word packets sent from ADP (x<=128) (not implemented)