4. Saving and Restoring the Fitting Parameters and Spectral Data
If you want to save your actual SPEX session, simply type: SPEX> save_event This command creates the files "summary.dat" and "spex_dflts.dat" in your IDL working directory. If you call SPEX again, you can continue where you left off by restoring the data with: SPEX> restore_event, /verb After you restore the event, you may need to type read_drm in order to get the correct RSM. SPEX allows you to export all the resulting parameters to an IDL save file, so that you can do any further analysis you are interested in outside of SPEX but within the IDL environment. An easy way to accomplish this is to call: SPEX> idl, spex_save_data, /all,
'spex07202_bpowfit_spectra.sav' Whenever we type idl, we use the command out of SPEX. The detail of SPEX commands can be found at "Analyzing Flare X-ray Spectra Using SPEX". Using the spex_save_data command, a file named "spex0723_bpowfit_spectra.sav" will be saved in our IDL working directory. It contains all the spectral data and fitting parameters we need for later use. We can get the detailed explanation of all saved variables from Richard Schwartz's help_spex.txt. Here I explain some of them for later use:
When we want to restore the data in an IDL session, type: IDL> restore, "spex0723_bpowfit_spctra.sav" Use the help command to see which variables are defined: IDL> help
| ||||||||||||||||||||||||||||||||||
|
This page last updated: June 27, 2011
|