!XLOADCT

             Adjust LUT
             ----------

    VDS data are displayed as a 2-d image.  A special
    lookup table is employed as the default.

    If you wish to change the current LUT, click on
    this button and the standard IDL routine XLOADCT
    will be loaded.

    Note that the original LUT can be reloaded via an
    option in the 'Reset' menu.


!BLANK
               Using the cursor on the image
               -----------------------------

    The action of the cursor within the image area
    depends on the setting of the 'Window Interaction'
    buttons.

    Note that when GIS is selected, the cursor has no
    effect in the plot area unless only ONE GIS band is
    displayed. The GIS band to display is selected with
    the buttons below and to the right of the plot
    area.

!CHECK_LLO

               Checking a database
               -------------------

    Not implemented yet.

    Eventually this function will allow the user to 
    check whether a database entry already exists that
    matches the current details in the mk_raster
    windows.

!CHECK_DWO
CHECK_LLO

!CHECK_RAF
CHECK_LLO

!CHECK_RAV
CHECK_LLO


!COMP10

               Compression
               -----------

    To reduce the amount of CDS data that has to be
    telemetered down, several data compression schemes
    have been provided in the on-board software.

    This menu allows the user to specify which
    compression scheme is to be used, together with, in
    some cases, a selection of the particular mode of
    operation for that scheme.

    The actual compression factors achievable by each
    of the schemes are TBD on real CDS data.

    In the meantime for the purposes of calculating the
    telemetry requirements, the following assumptions
    are made:

           Scheme                Compression factor
      1 (straight copy)                   1
      2 (truncate 12 bits)              1.33
      3 (VBWL - all options)          2.0
      4 (Sum over lines)             defined by window size
      5 (Sum over window)           defined by window size

!COMP20
COMP10

!COMP30
COMP10

!COMP31
COMP10

!COMP32
COMP10

!COMP33
COMP10

!COMP34
COMP10

!COMP35
COMP10

!COMP36
COMP10

!COMP37
COMP10

!COMP40
COMP10

!COMP50
COMP10

!COMP60
COMP10



!GISB1

             Display GIS band
             ----------------

    In order to interact with GIS data, only one band
    of data may be displayed (a warning message is
    given otherwise).  Set the band to be displayed
    using these buttons.  

    For purely display purposes, all four bands can be
    displayed by selecting 'All'.


!GISB2
GISB1

!GISB3
GISB1

!GISB4
GISB1

!GISB5
GISB1


!GIS_SEEG

             GIS setup parameters
             --------------------

    Select this to get a display of the GIS setup
    parameters.

!GIS_DEWS

             GIS extraction windows
             ----------------------

    Select this to see a plot of the GIS extraction
    windows.




!DISP_ALL

                      Display mode
                      ------------

    These buttons allow the user to change the mode of
    display of the data.

    ALL - means that the full wavelength range of data
    will be displayed and line windows will be
    superimposed upon that display.

!DISP_WONLY

                      Display mode
                      ------------

    WINDOWS - means that only data within the defined
    line windows will be displayed.  For the VDS they
    are still displayed in their 'correct' location
    within the overall maximum possible image area. 
    For the GIS, separate plots are given for each
    window - these can quickly become illegible when
    the number > 4


!DISP_FONLY
                      Display mode
                      ------------

    FLAGS - signifies that only the data from  windows
    designated as flag windows are to be displayed. 
    See FLAG mode under 'Window  interaction mode'.


!EXIT_QUIT

                  Exit, quietly
                  -------------

    When MK_RASTER is finished you may either chose a
    quiet exit with this menu selection.  If an input
    parameter was supplied, the full mk_raster
    structure will be contained within it on exit from
    mk_raster.

!EXIT_SAVE

                  Exit, and save structure
                  ------------------------

    This exit option will automatically save the
    mk_raster structure in an IDL save file
    (mk_raster_struct.save). If you RESTORE that file
    in the futrue, the save structure will be in the
    variable tp_obs.


!ETRANGE

           Exposure time
           -------------

    You may type in the required exposure time here if
    you do not like using widget sliders.
  

!ERANGE1

           Exposure time
           -------------

    Use the slider to set the exposure time (in
    seconds) required.  The range of values selectable
    on the slider is controlled by the selection made
    in this menu.

    Note that the maximum exposure for the VDS is 1023
    seconds.

    If you don't like sliders, the required value may
    also be typed in the exposure time display box.

!ERANGE2
ERANGE1

!ERANGE3
ERANGE1

!ERANGE4
ERANGE1

!ERANGE5
ERANGE1

!ET_SLIDER
ERANGE1


!GDEFEX_1

           GIS default extraction 
           ---------------------- 

    Use the buttons provided to select ALL the data 
    from the selected detector.  This is done 
    independently of whether any spectral lines are
    selected in that region and this setting overrides
    the existence of any spectral lines.

    For instance if you switch on selection of all GIS1
    data, you will get all GIS1 data (see the plot of
    data extraction windows) even if  some particular
    spectral lines are also defined within the range of
    GIS1.

!GDEFEX_2
GDEFEX_1

!GDEFEX_3
GDEFEX_1

!GDEFEX_4
GDEFEX_1


!FUND

           Current Fundamental Raster Description
           --------------------------------------

    Each entry in the databases has a description
    associated with it.  The description automatically
    associated with the Fundamental Raster is displayed
    in this box. 

    NB. Even though this widget is editable, at the
    moment any user input is overwritten by the
    automatic  compilation of the description.


!VARI

           Current Raster Variation Description
           ------------------------------------

    Each entry in the databases has a description
    associated with it.  The description automatically
    associated with the Raster Variation is displayed
    in this box. 

    NB. Even though this widget is editable, at the
    moment any user input is overwritten by the
    automatic  compilation of the description.

!LINE

               Current Line List Description
               -----------------------------

    Each entry in the databases has a description
    associated with it.  Enter the description (max 50
    chars.) to be associated with the Line List in this
    box.
    
    NB. This is the only description (of the four) that
    requires user input.  It is always safer to hit
    'return' after entering the description.


!DWIN

         Current Data Extraction Window Description
         ------------------------------------------

    Each entry in the databases has a description
    associated with it.  The description automatically
    associated with the Data Extraction Windows is
    displayed in this box. 

    NB. Even though this widget is editable, at the
    moment any user input is overwritten by the
    automatic  compilation of the description.

    Note that if this window contains the message
    'Too many data windows', it means it!  Reduce
    the number of spectral lines specified.


!EDIT_LINE

               Edit line list
               --------------

    Although the specification of spectral lines can be
    done graphically using the cursor in the image
    window below, sometimes it is preferable to edit
    the numerical entries directly.  Selecting this
    button will take you  into a mode where the line
    list can be edited.


!VDS_SEEV

               See VDS setup parameters
               ------------------------

    This selection will allow you to see the various
    setup parameters applicable only to the VDS
    detector.


!USER_CDS_DB

               Selection of databases
               ----------------------

    This button allows TOGGLING between the 'official'
    and 'private' databases.  The entry default is to 
    use private databases (in the directory specified
    by  the environment variable ZDBASE_USER). 
    Pressing this button will toggle to using the CDS
    databases (in the directory ZDBASE_CDS).  A message
    about the current directory in use is given in the
    message window.


!NDATA_CORO

               Selection of display data
               -------------------------

    This menu allows the user to select which kind of
    data is to be displayed in the image area.  At the
    moment line lists and their predicted intensities
    are only available for QUIET and ACTIVE regions.

!NDATA_QUIET
NDATA_CORO

!NDATA_ACTIVE
NDATA_CORO

!NDATA_LIMB
NDATA_CORO

!NDATA_CHOLE
NDATA_CORO

!NDATA_FLARE
NDATA_CORO


!HELP_GENERAL

                    General overview
                    ----------------

    A general selection of help information is
    available by selecting this entry.


!HELP_ALL

               Hard copy of raster etc. details
               --------------------------------

    If this entry is selected, a printout will be
    produced of details of the current raster, its
    variation, the line list and the derived data
    window extraction list.


!HELP_RAS

             Hard copy of fundamental raster details
             ---------------------------------------

    If this entry is selected, a printout will be
    produced of details of the current fundamental
    raster.


!HELP_LIN

             Hard copy of line list details
             ------------------------------

    If this entry is selected, a printout will be
    produced of details of the current line list.


!HELP_DWI

             Hard copy of data extraction window details
             -------------------------------------------

    If this entry is selected, a printout will be
    produced of details of the current data window
    extraction list.


!WRITE_ALL

                 Storing information in the databases.
                 -------------------------------------

    Once the details of the required raster and its
    dependents have been defined, the information
    should be stored in the  databases, either your
    private ones or, if you have the privilege, in the
    project databases.  It is possible to store the
    information on the fundamental raster, the
    variation, the line list and the extraction windows
    separately using the  other selections in this
    menu.  This selection will attempt to  write
    entries for all of those.  If the entry is new then
    an  ID number will be assigned.  If the entry
    already exists a  message to that effect is given,
    and the existing ID shown.

    NB it is strongly recommended that this selection
    (ie ALL) is used to store details even if only a
    minor change has been made to the information (eg
    adding background windows). Its  use does not
    result in any storage of redundant information but
    may save a lot of confusion.
 
!WRITE_LLO

                 Storing information in the databases.
                 -------------------------------------

    If you are determined to be an expert, use this
    selection to save the current line list only in the
    appropriate database.


!WRITE_DWO

                 Storing information in the databases.
                 -------------------------------------

    If you are determined to be an expert, use this
    selection to save the data extraction window list 
    only in the appropriate database.


!WRITE_RAF

                 Storing information in the databases.
                 -------------------------------------

    If you are determined to be an expert, use this
    selection to save the fundamental raster definition 
    only in the appropriate database.


!WRITE_RAV

                 Storing information in the databases.
                 -------------------------------------

    If you are determined to be an expert, use this
    selection to save the raster variation only in the
    appropriate database.


!WRITE_HELP

                 Storing information in the databases.
                 -------------------------------------

    This will give some help (warnings) about the use
    of any selection in this menu other than the 'save
    all' option.


!INST1

              NIS Instrument
              --------------

    The CDS has two instruments, the Normal Incidence
    and Grazing Incidence Spectrographs (NIS or GIS).  

    The NIS (selected by this button) covers the 
    wavelength regions (310-380)A and (517-633)A  in
    two  separate spectra.

    Various other selectable items are only relevant to
    one instrument or the other. The appropriate
    windows to allow their selection are made available
    when the instrument is chosen.


!INST2

              GIS Instrument
              --------------

    The CDS has two instruments, the Normal Incidence
    and Grazing Incidence Spectrographs (NIS or GIS).  

    The GIS (selectable with this button) has four 
    detectors covering the approximate wavelength
    ranges 

    155 - 224
    261 - 346 
    395 - 496 
    662 - 787 A respectively.

    Various other selectable items are only relevant to
    one instrument or the other. The appropriate
    windows to allow their selection are made available
    when the instrument is chosen.




!SSSX

              Mirror step size
              ----------------

    Enter in this box the size of steps to be made by
    the Mirror during a raster.  The values are in
    arcseconds.  

    One mirror step corresponds to approximately 2
    arcsecs. Only integer steps of the mirror are
    possible so this box will only accept values which
    are a multiple of 2. 

    The FITS data file will reflect the true size of
    the mirror steps (ie 2.034 arcsec)  


!SSSY
              Slit step size
              --------------

    Enter in this box the size of steps to be made by
    the Slit during a raster. The values are in
    arcseconds.  

    One slit step corresponds to approximately 1
    arcsec.   Only integer steps of the slit are
    possible.  

    The FITS data file will reflect the true size of
    the slit steps (ie 1.017 arcsec)  

    NB.  It is not possible to move the slit when using
    the NIS.  This box is therefore not editable when
    the NIS instrument is selected.


!NSX

              Mirror locations
              ----------------

    Enter in this box the number of LOCATIONS at which
    the mirror is to be set during a raster scan.

    Remember also to enter the NUMBER of sample points 
    for the mirror NOT the number of steps to be made
    during the raster. A degenerate raster (ie a single
    sample position) will, therefore, have (1,1) mirror
    and slit positions and the step size will be
    irrelevant.  A raster with (3,3) positions and a
    step size of (10,10) arcseconds will sample data
    over only a (20,20) arcsecond area (neglecting the
    actual slit size).

    Note that the logic of a 2-d raster using mirror and
    slit steps is 

    for number of raster repeats     (set in mk_study)
       for each mirror posn
          for each slit posn
             expose
          endfor
       endfor
    endfor

    This logic applies even if the step size degenerates
    to zero (ie a sit and stare raster)




!NSY


              Slit locations
              --------------

    Enter in this box the number of LOCATIONS at which
    the slit is to be set during a raster scan.

    NB.  The number of slit locations is NOT applicable
    to rasters which use the NIS - this box is
    therefore not editable when that instrument is
    selected.

    Remember also to enter the NUMBER of sample points 
    for the slit NOT the number of steps to be made
    during the raster. A degenerate raster (ie a single
    sample position) will, therefore, have (1,1) mirror
    and slit positions and the step size will be
    irrelevant.  A raster with (3,3) positions and a
    step size of (10,10) arcseconds will sample data
    over only a (20,20) arcsecond area (neglecting the
    actual slit size).

    Note that the logic of a 2-d raster using mirror and
    slit steps is 

    for number of raster repeats     (set in mk_study)
       for each mirror posn
          for each slit posn
             expose
          endfor
       endfor
    endfor

    This logic applies even if the step size degenerates
    to zero (ie a sit and stare raster)



  

!RESET_ALL

            Reset (ALL)
            -----------

    This reset menu is provided to allow various parts
    (or all) of the MK_RASTER parameters to be reset to
    default values.  

    Selecting the 'ALL' option will clear all
    parameters to their entry defaults.

!RESET_RAS

            Reset (RASTER)
            --------------

    This reset menu is provided to allow various parts
    (or all) of the MK_RASTER parameters to be reset to
    default values.  

    Selecting the 'RASTER' option will clear all those
    parameters affecting the setup of the raster but
    excluding parameters associated with the lines and
    data extraction windows.


!RESET_LWO
            Reset (LINE WINDOWS)
            --------------------

    This reset menu is provided to allow various parts
    (or all) of the MK_RASTER parameters to be reset to
    default values.  

    Selecting the 'LINE WINDOW' option will clear all
    those parameters associated with the lines and data
    extraction windows.



!RESET_FLA
            Reset (FLAG WINDOWS)
            --------------------

    This reset menu is provided to allow various parts
    (or all) of the MK_RASTER parameters to be reset to
    default values.  

    Selecting the 'FLAG WINDOW' option will clear 
    the association of data extraction windows as
    'flag' windows.




!RESET_LUT
            Reset (DISPLAY LUT)
            --------------------

    This reset menu is provided to allow various parts
    (or all) of the MK_RASTER parameters to be reset to
    default values.  

    Selecting the 'DISPLAY LUT' option will reset
    the display LUT to its default.




!RESET_DET
            Reset (DETECTOR PARAMETERS)
            ---------------------------

    This reset menu is provided to allow various parts
    (or all) of the MK_RASTER parameters to be reset to
    default values.  

    Selecting the 'DETECTOR PARAMETERS' option will reset
    the user-settable VDS parameters (orientation and
    map option) to their default values.






!DBASE_RASP

          Selection a raster from the databases
          -------------------------------------

    This menu selection will allow the user to select a
    fundamental raster and any of its variations from
    the available and selected database.

    Since the line list ID and data extraction window 
    list ID are contained within a raster variation
    definition, the line and window lists, defined by
    the raster variation will also be loaded.


!DBASE_LINE

    Selection a line/data extraction list from the databases
    --------------------------------------------------------

    This menu selection will allow the user to select a
    line list and any of its associated window
    extraction lists from the available and selected
    database.

    The raster and variation details are not changed
    (except the line and window list IDs contained in
    the raster  variation are set to zero (undefined).


!SLIT1
                       
             Slits 
             -----

    The choice of which slit to use is made by a
    pull-down-menu selection.  CDS has 6 slits
    available, and each detector can use any of the
    six.

    The numerical values quoted in parentheses are the
    slit sizes in arcseconds.

    It is anticipated that the NIS will normally be
    used with the long (240 arcsec) slits and the GIS
    with the smaller 2 or 4 arcsec square slits.

    The large (90x240) slit is intended for
    overlappagram type images.

!SLIT2
SLIT1

!SLIT3
SLIT1

!SLIT4
SLIT1

!SLIT5
SLIT1

!SLIT6
SLIT1





!EXTE_YES

           VDS background windows
           ----------------------

    Use these buttons to determine whether VDS
    background windows will be used in the data
    extraction scheme or not.

    This button turns the background windows ON ie. 
    they will be included in the data extraction list
    (but not the line list).

    See the general help for a further discussion on
    the use of background windows.

!EXTE_NO

           VDS background windows
           ----------------------

    Use these buttons to determine whether VDS
    background windows will be used in the data
    extraction scheme or not.

    This button turns the background windows OFF ie. 
    they will be NOT be included in the data extraction
    list.

    See the general help for a further discussion on
    the use of background windows.

!EXTE_RES

           VDS background windows
           ----------------------

    This button allows the user to resize the
    background windows.  Note that the locations of the
    windows are fixed and defined in a data file. 

    See the general help for a further discussion on
    the use of background windows.



!NDEFEX_1

             VDS default extraction
             ----------------------

    It is possible to specify that you want wholesale
    extraction of the VDS data (either all spectral
    band 1 or all band 2 or all the CCD) by setting
    these buttons.  They will override any spectral
    line selections within that band.  See the plot of
    data extraction windows to see what you have done.

!NDEFEX_2
NDEFEX_1

!NDEFEX_3
NDEFEX_1



!VDS_OR_0

             VDS parameters
             --------------


    The VDS ORIENTATION determines whether the data are
    extracted from the CCD by rows or columns.  This
    has certain advantages for some of the compression
    techniques.

!VDS_OR_1
VDS_OR_0

!VDS_MAP2

             VDS parameters
             --------------

    The CDHS MAP option allows VDS data to be read from
    the CCD into memory and then telemetered down
    (normal) or for the data to stay in memory and be
    accumulated with the next exposure's data. (I
    think???)

!VDS_MAP3
VDS_MAP2


!VDS_MOD1

             VDS parameters
             --------------

    The VDS READOUT mode under normal operations is
    expected to be 'quadrant' - see help on VDS
    background.  It is anticipated that only a hardware
    anomaly will force a change from this.

!VDS_MOD2
VDS_MOD1

!VDS_MOD3
VDS_MOD1

!VDS_MOD4
VDS_MOD1

!VDS_MOD5
VDS_MOD1

!VDS_MOD6
VDS_MOD1

!VDS_MOD7
VDS_MOD1


!VDS_VOLT

             VDS parameters
             --------------

    The MCP VOLTAGE affects the gain of the detector
    and certain calibrations (eg linearity) are
    voltage-dependant.


!VDS_OFF3
             VDS parameters
             --------------


    Owing to optical misalignments the two VDS spectra
    will not lie exactly parallel to the CCD rows and
    will not abut at the CCD centre.  The VDS OFFSETS
    are provided to allow the data extraction windows
    to find the spectra when they are not at the
    nominal position.

    Note that the offset in the 300A range is
    considered negative ie it moves the location of the
    actual spectrum away from the CCD centre row.

!VDS_OFF5
VDS_OFF3


!VDS_DEWS

    PLOT EXTRACTION WINDOWS allows the user to see the
    extraction windows and VDS hardware windows that
    result from the current setup.


!WH_SLIDER

             Window Height
             -------------

    For the VDS spectra it is possible to limit the
    extent of the spatial information retrieved from
    the long slit images.  The 'normal' (2x240) VDS
    slit will give spectral information from a region
    along the slit covering 240 arcseconds.  If for
    some reason a smaller spatial coverage is required,
    use the window height parameter to change the
    extent of the spatial data returned.  A single
    value will apply to all windows.


!WWRANGE3
                 Extraction window width
                 -----------------------

    The width of extraction windows may be set with the
    slider below.  The scale of values represented by
    the slider is set here - either [0,100] or [0,1000]


!WWRANGE4
WWRANGE3


!WW_SLIDER
                 
                 Extraction window width
                 -----------------------

    Use this slider to set the extraction window width.
    The scale of the slider is set in the menu above. 
    You may also just type in a value in the box.

!WWRANGE

                 Extraction window width
                 -----------------------

    If you do not like sliders, you may type in an
    extraction window width here (in pixels).



!LINE_ADD

                 Window interaction mode
                 -----------------------

    In order for the user to be able to interact via
    the cursor with the display window in a variety of
    ways, the mode of interaction must be explicitly
    set.   Set one of these mutually exclusive buttons
    to select that mode.  Note that for GIS no
    interaction is allowed until the display is in
    single-band mode - see "Display GIS band".

    ADD - will add a line to the current line list
    (this can be used to start a line list as well). 
    The line window will have the characteristics as
    defined by the current MK_RASTER settings.  The
    line will be centred on the clicked cursor
    position.  A maximum of 20 lines is currently
    accepted.

!LINE_DELETE

                 Window interaction mode
                 -----------------------

    In order for the user to be able to interact via
    the cursor with the display window in a variety of
    ways, the mode of interaction must be explicitly
    set.   Set one of these mutually exclusive buttons
    to select that mode.  Note that for GIS no
    interaction is allowed until the display is in
    single-band mode - see "Display GIS band".

    DEL - will delete a line from an existing list.  In
    this mode just click on any pixel within the line
    window to have the line deleted.

!LINE_MOVE

                 Window interaction mode
                 -----------------------

    In order for the user to be able to interact via
    the cursor with the display window in a variety of
    ways, the mode of interaction must be explicitly
    set.   Set one of these mutually exclusive buttons
    to select that mode.  Note that for GIS no
    interaction is allowed until the display is in
    single-band mode - see "Display GIS band".

    MOV - allows the user to move line windows around. 
    Click on any pixel within the line window to 'pick
    up' the line.  The line will be moved to a position
    centred on the cursor when the cursor button is
    released. It will not simply be moved by a distance
    corresponding to the cursor movement from button
    press to release. Note that windows cannot move
    from one spectrum to another, in other words only
    the horizontal value of the cursor is read.

!LINE_IDENT

                 Window interaction mode
                 -----------------------

    In order for the user to be able to interact via
    the cursor with the display window in a variety of
    ways, the mode of interaction must be explicitly
    set.   Set one of these mutually exclusive buttons
    to select that mode.  Note that for GIS no
    interaction is allowed until the display is in
    single-band mode - see "Display GIS band".

    ID - gives details of the spectral line contained
    within the window or just details of the cursor
    position and the data value at that point if the
    cursor is not within a defined window.

!LINE_FLAG

                 Window interaction mode
                 -----------------------

    In order for the user to be able to interact via
    the cursor with the display window in a variety of
    ways, the mode of interaction must be explicitly
    set.   Set one of these mutually exclusive buttons
    to select that mode.  Note that for GIS no
    interaction is allowed until the display is in
    single-band mode - see "Display GIS band".

    FLAG - will nominate as a flag window any window
    identified (up to a maximum of 3). To clear the
    flag window definitions, use the RESET option.

!LINE_PROF

                 Window interaction mode
                 -----------------------

    In order for the user to be able to interact via
    the cursor with the display window in a variety of
    ways, the mode of interaction must be explicitly
    set.   Set one of these mutually exclusive buttons
    to select that mode.  Note that for GIS no
    interaction is allowed until the display is in
    single-band mode - see "Display GIS band".

    PROF - will enter the profile display mode. 
    Currently only uses crudest profiling routine. Will
    be upgraded when Stein Vidar rejoins the fray. Exit
    by pressing the right hand mouse button.