From freeland@sxt1.space.lockheed.com Thu Nov 14 09:02:33 1991
Received: by sxt1.space.lockheed.com (5.57/Ultrix3.0-C)
	id AA00314; Wed, 13 Nov 91 16:00:14 PST
Date: Wed, 13 Nov 91 16:00:14 PST
From: freeland@sxt1.space.lockheed.com (Samuel L. Freeland)
Message-Id: <9111140000.AA00314@sxt1.space.lockheed.com>
To: morrison@isass2.solar.isas.ac.jp, tsuneta@flare1.solar.isas.ac.jp
Subject: Guard Band Multiplier Modification
Cc: acton@isass1.solar.isas.ac.jp, hara@flare1.solar.isas.ac.jp,
        hudson@isass2.solar.isas.ac.jp, lemen@isass2.solar.isas.ac.jp,
        shimizu@flare1.solar.isas.ac.jp
Status: R

FROM: S.L.Freeland
TO:   Saku Tsueneta, Mons Morrison
SUBJ: Guard Band Multiplier Modification

Dear Tsuenta san & Morrison san.

The following patch will increase the guard band multiplier from 4 to 8 and
adjust the checksum table to reflect this change.  Note that only the 
commands which indicate SXTE-U address and data are listed here.


Command			  		Effect
______________________  	______________________________________________
BC 83H 46H F6H 01H 00H          Change guard band multiplier from 4 to 8
BC 83H 4FH 46H 01H 31H		Update checksum table*
______________________________________________________________________________

* The new value for the checksum assumes the setup flush parameter has also
  been updated to the newest value (Address 46E9H, data value 07H)

Additional increases in this factor are as easily possible (1 byte patch) if the
need arises, but remember the readout time overhead... 

Sam. 
 